Resolved: Fixed in Luna HSM Client 10.6.0. Problem: When using lunacm.exe -f to run a list of scripted LunaCM commands, the script does not continue running after encountering an error. The ReceiveTimeout setting now applies to the NTLS handshake as well. If the NTLS handshake succeeds, the custom timeout setting is observed as expected. Problem: When Luna HSM Client is configured with a receive timeout less than the default 20000 ms ( LunaSA Client =, for example), an unsuccessful NTLS handshake still waits 20000 ms to time out. Issues listed in green have been resolved and the component and version including the fix is provided. Use the buttons below to display issues related to specific Luna software/firmware components. Workarounds are provided where available. The following table lists known issues in all released versions of Luna 7 components. These archived documents are not updated, and may contain errors and omissions. Select a release to view the available documentation for the release. Older versions of the documentation are release-specific. You are viewing the latest version of the Luna PCIe HSM 7 documentation, which covers all released Luna PCIe HSM 7 and Luna HSM Client 7/10 components, and is updated frequently with the latest corrections and improvements.